Following a changing heat-pump fault in Southeast Magnolia
Multiple thermostat errors and a system that would not run brought us to this Southeast Magnolia home. A power cycle initially restored operation, but later visits uncovered refrigerant-flow and heating-changeover problems that required separate attention.
Investigating the refrigerant restriction
The first visit checked error history and connected remote monitoring to retain operating information. Later testing found a restriction at the refrigerant metering valve, known as the TXV.
The inlet screen was removed and the valve was subsequently replaced. When the problem continued, the technician recovered the refrigerant and installed a fresh charge. Cooling then improved substantially.
The heating changeover still failed
The outdoor reversing valve did not receive its heating command, even though the display reported a heating mode. The technician suspected the outdoor control board and called for further diagnosis.
The result was therefore partial: the later refrigerant work produced strong cooling during testing, but heating operation was still unresolved. The history gives the homeowner a clear separation between the completed valve-and-charge work and the control problem that still needed investigation.