Finding a delayed condensate shutdown in Sammamish
The furnace at this Sammamish home initially responded when its thermostat was set to heat. Longer testing then revealed another problem: condensate removal failed and triggered the flood-prevention safety. The operating check needed to continue beyond the first successful ignition.
Replacing the condensate assembly
Our technician replaced the failed condensate evacuation assembly after the extended run exposed its failure. The furnace had lit successfully through multiple starts before that later shutdown appeared.
The inspection also found substantial airflow restriction, exhaust-assembly noise and signs of aging in the controls. Those remained separate concerns to discuss, rather than work automatically resolved by the water-removal repair.
Later control check
A subsequent visit again found the thermostat set to off. Selecting heat brought the furnace on, and both stages and the condensate system were checked as functional.
The history distinguishes an operating-mode issue from a real component failure. One was addressed through the control setting; the other required replacement during the earlier extended assessment.
Need help with your heating system?
Tell us what the equipment is doing and when the problem appears.