Repairing a rooftop refrigerant connection in Roxhill

The mini-split stopped cooling while roofing work was taking place at this Roxhill home. The homeowner reported that it had worked beforehand. Our technician investigated the refrigerant circuit and found a failed connection at the rooftop line set.

Rooftop refrigerant connection repair service photo at the Roxhill home
Equipment documented during the Roxhill service visit.

Isolating and testing the connection

We recovered refrigerant, isolated system components and pressure-tested them. The rooftop connection had lost its seal; the technician considered movement of the lines during the roofing work a likely contributor.

The connection was repaired, and the system was evacuated to remove moisture and other gases. A further pressure check verified the repair before the equipment was recharged.

Cooling tested after repair

The system was placed back into operation and produced approximately a twenty-degree temperature difference during testing. The technician recorded proper operation at the end of the visit.

The repair addressed the located connection rather than simply adding refrigerant to equipment that was still leaking. Continued maintenance was recommended to observe condition and performance after the completed work.