Cleaning a furnace sensor and finding drainage concerns in North Admiral
The furnace at this North Admiral home was not igniting and staying lit consistently. Inspection found a very dirty flame sensor, an igniter reading outside the technician's acceptable range, and a separate condensate problem near the inducer assembly.
Cleaning the flame sensor
Our technician cleaned the flame sensor during the visit. The furnace was working at the end of the appointment, but the inspection also identified conditions that needed further repair consideration.
The inducer condensate drainage was not connected correctly. Water was draining onto the transformer, where substantial rust was visible. That was a different finding from the dirty flame sensor and required its own place in the repair discussion.
Explaining what still needed attention
An estimate was sent for the additional work, including the out-of-range ignition component and drainage concerns. The service summary does not document those proposed repairs as completed.
The homeowner therefore had heat during the visit and a clear set of remaining findings. Cleaning a sensor addressed one immediate condition, while an aging ignition component and water reaching electrical equipment still needed a follow-up decision. The diagnosis kept these concerns together without presenting the working furnace as proof that all faults had been corrected.