Following a condensate failure and blank thermostat on Mercer Island
The thermostat went blank and the air conditioner stopped responding at this Mercer Island home. Inspection found a fractured condensate-pump reservoir. The water-related fault needed attention before normal control could be confirmed.
Replacing the damaged pump assembly
Our technician replaced the pump and reservoir. The condensate-removal assembly then worked, but a wet safety switch still prevented a full operating test until it had dried.
The pan holding the pump also appeared to leak, and an estimate was planned for that separate replacement. The initial appointment therefore completed the pump assembly without establishing that every water-protection issue had been resolved.
Resetting a switch that stayed off
The homeowner later reported that the system had not resumed operation. A return visit found that the water safety switch had not reset after drying. The technician manually reset it and the system began functioning.
The history connects the broken reservoir, protective shutdown and later reset. It shows why replacing the failed pump alone was not the final operating step. The pan replacement remained a recommendation in the reviewed record.