Addressing water held in a Madrona furnace’s intake piping
A small piping detail became the main maintenance task at this Madrona home. Evergreen inspected a 90% gas furnace that was functioning, then found water held in its two-inch PVC intake. The intake pipe did not have slope, so the visit focused on correcting that condition as part of caring for the existing furnace.
Finding where water was collecting
The technician documented that the furnace was functional and working well during the appointment. The specific issue was in the intake piping: without grade, water was staying in the pipe instead of having a route out.
That finding illustrates why a checkup can be useful even when a homeowner is still getting heat. Looking at the connected piping can identify a maintenance need beyond the burner and blower components inside the cabinet.
Adjusting the route to the exterior
The technician corrected the intake arrangement so it had grade toward the outside of the home. A new wall opening was drilled for the adjusted route, and both the new and previous openings were sealed and siliconed. Those were tasks completed during this visit.
For the household, the goal was to look after the furnace already in service and address the water-holding condition before simply continuing with normal use. The work concentrated on a defined piping problem, with the completed record identifying both the slope adjustment and the attention to sealing the openings at the home’s exterior.