Reworking condensate drainage after intermittent heat in Kent
The furnace heated intermittently at this Kent home. The first visit found condensate in pressure-switch tubing and a furnace drain path that needed improvement. Clearing that water allowed a heating run, followed by a planned drainage correction.
Reconfiguring the condensate path
Our technician installed a condensate pump and reworked the furnace and indoor-coil drain lines into it. An easy-clean trap was added for the coil.
Vinyl discharge tubing was routed through the crawlspace beside the refrigerant lines and terminated near the outdoor unit. The penetrations were sealed, and the pump was connected as a safety device.
Keeping drainage and airflow in view
The earlier visit also identified a heavily loaded filter for the homeowner to replace. That was separate from the drainage components installed during the return appointment.
Later maintenance checked the drain and pump and recorded functioning equipment. The completed history connects the intermittent heat to water affecting a pressure-control path, then documents a revised water-removal arrangement rather than repeated resets alone.
Need help with your heating system?
Tell us what the equipment is doing and when the problem appears.