Investigating upstairs cooling through a High Point attic
The upstairs area was not cooling as expected at this High Point home. Testing showed that the attic equipment was producing cooling and had airflow, so our technician looked beyond the unit itself at the ductwork and the hot space surrounding it.
Comparing air temperatures and duct routing
The flexible ductwork had pinched areas at bends and connections. The technician also measured about a ten-degree difference between air coming from the home and the air entering the equipment. The attic was very warm during the visit, making heat gain along that path a possible contributor to the upstairs complaint.
No definite equipment fault was reproduced during those operating checks. A refrigerant-balance test was discussed as a way to verify charge more directly, and the homeowner requested an estimate to consider. The visit did not establish a completed refrigerant correction.
Later water findings were addressed separately
A later visit at the same home found uninsulated copper behind an indoor unit allowing condensation to collect and drip. Our technician added insulation, tested water through the drain, and secured the drain hose. No cracks were found in the inspected pan or hose. The later work did not establish that the original upstairs temperature concern had been resolved.
That later appointment also renewed the recommendation for a refrigerant-balance check because the upstairs performance question remained. An additional protective drain pan was proposed for the attic equipment. Those recommendations were separate from the insulation and drainage work completed.