Following a recurring water-safety error in Greenwood
The Greenwood system had been down with a water-safety error. Initial checks found the condensate drain and safeties working during testing, and a power cycle restored operation. Later visits were needed when the error returned.
Looking beyond a successful reset
The code indicated a wet-switch concern. A second assessment again found the pump and switch functional during tests, showing why a reset alone had not established the underlying cause.
During a later service visit, the technician found that the drain pan was not level. Water was collecting on the wrong side and triggering the protective response.
Leveling the pan and checking operation
After testing with the pan leveled, the repeated shutdown stopped during the visit. That appointment also included equipment cleaning and checks of filters, airflow resistance, thermostat operation, drains and cooling output.
Normal operation was recorded at departure. This history takes the homeowner's repeated error beyond the temporary success of restarting equipment, with a later physical drainage finding that explained the unwanted safety response during testing.