Finding the refrigerant leak behind lost cooling in East Queen Anne
Resetting the equipment had not brought the cooling back. At this East Queen Anne home, the outdoor unit was running, but the Mitsubishi system was not doing the job indoors. The first diagnostic visit found a refrigerant leak near the branch box, leading to a dedicated leak-search and repair visit.
Isolating the leaking connections
The original technician checked temperatures and inspected the refrigerant connections after confirming the cooling problem. A full leak search was needed to establish the repair scope, and the homeowner approved the return visit.
At that visit, the system had no standing refrigerant pressure. We isolated its components and found two failed connections at the branch box. Those specific findings gave the repair a defined target rather than treating the loss of cooling as something another restart would solve.
Repairing, testing and bringing the cooling back
Our technician repaired the connections and pressure-tested the system. It passed both the positive-pressure and vacuum checks. We then recharged the equipment and ran it to check the result. The system came on and began producing cooling.
The equipment was functioning properly at the end of the visit. For the homeowner, the work connected the original symptom to a located leak, completed connection repairs and an operating check afterward. Continued maintenance was recommended. The service photo shows the refrigerant piping inspected during the repair process.